Skip to content
ScienceDirrect

Journal of Taibah University Medical Sciences

Date: 11 June 2026

Volume 21, Issue 4 · Pages: 651–662

Show more⌄
Original Article● Open accessUnder a Creative Commons license ↗
Original Article

Association between pedicle screw dimensions and pedicle morphometry in computed tomography scans

Show more⌄

Abstract

Background: Previous studies have investigated the morphometry of vertebrae and the general concept of pedicle breach. However, direct correlations have not been established between pedicle morphometry and screw dimensions. This study aimed to determine the relation- ship between the size and direction of pedicle screws and the morphometry of the pedicles of thoracolumbar vertebrae, which were assessed using computed tomog- raphy (CT) scans. Methods: This single-center, retrospective observational study included 60 adult patients admitted with thoracic and lumbar vertebral fractures who underwent posterior spinal stabilization between October 2018 and November 2023. Pre- and post-operative CT scans were analyzed to assess the pedicle and vertebral morphometry, screw di- mensions, and breach grade. Paired tests and correlation analyses were performed. Results: In total, 177 vertebrae (354 pedicles) were analyzed in 60 patients. Most fractures were burst type (85%), mainly at T12—L1. Post-operative pedicle width (p < 0.001) and height (p < 0.001) significantly increased. The screw insertion angles had no correlation with the transverse pedicle angle. Narrow thoracic pedicles and * Corresponding address: Department of Orthopaedics, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, India. E-mail: shyambhat.n@manipal.edu (S.N. Bhat) Peer review under responsibility of Taibah University. Production and hosting by Elsevier

Keywords
Computed tomography (CT) scan; Pedicle; Pedicle of vertebra; Risk of breach; Thoracolumbar; Thor- acolumbar fractures � 2026 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

Authors and affiliations

Anusha Shetty, Shyamasunder N. Bhat, Raghuraj S. Kundangar; Madhava Pai K

Author affiliations are listed in the full article PDF.

Full article

Open the full article PDF

How to cite

Anusha Shetty, Shyamasunder N. Bhat, Raghuraj S. Kundangar; Madhava Pai K. (2026). Association between pedicle screw dimensions and pedicle morphometry in computed tomography scans. Journal of Taibah University Medical Sciences, Volume 21, Issue 4, 651–662. DOI: 10.1016/j.jtumed.2026.05.013.

All content on this site: Copyright © 2026 Elsevier B.V., its licensors, and contributors. All rights are reserved, including those for text and data mining, AI training, and similar technologies. For all open access content, the relevant licensing terms apply.
RELX